DS200SDCCG5A Drive Control Card
IN STOCK
REMAN
REPAIR
NEW
Part Number: DS200SDCCG5A
Manufacturer: General Electric
Series: MKV
Request a Quote
DS200SDCCG5A Drive Control Card
The DS200SDCCG5A is the primary controller for the drive system, orchestrating and fine-tuning the intricate dance of the drive’s operations.Â
It boasts advanced capabilities in NOx detection, temperature management, humidity control, and system loss minimization.Â
With three microprocessors and 64 KB of RAM, this card is designed to execute control tasks with utmost precision, ensuring the drive system operates exactly as intended.
Â
Microprocessors: 3
RAM: 64 KB
EPROM: 5
Dimensions: 12.5″ x 6.5″ x 1.5″
Weight: 1.5 lbs
Features
NOx Detection: Advanced NOx detection capabilities enable real-time monitoring and management of nitrogen oxide levels.
Emergency Overspeed Protection: Provides critical emergency overspeed protection, safeguarding the turbine from potential damage.
Input/Output Interface: This interface acts as a vital input/output point, facilitating seamless communication and control within the turbine system.
Firmware and Hardware Processing: Equipped with cutting-edge firmware and hardware processing capabilities for efficient control signal processing.
EPROM Connectors: Five EPROM connectors allow for the storage of configuration software, enabling customization and optimization of drive control parameters.
Configuration Parameters Storage: Four EPROM modules store factory-assigned configuration parameters, while the fifth module allows user or servicer-assigned configurations.
Troubleshooting Support: Includes jumpers for configuration, connectors for attaching auxiliary cards, and standoffs for additional card connections, aiding in troubleshooting and system expansion.
Compatibility
The DS200SDCCG5A is meticulously designed to seamlessly integrate with GE’s Speedtronic MKV gas turbine control system.Â
Tailored specifically for gas turbines, it is optimized for compatibility within this specific system and is not intended for use with other turbine types or control systems.
Benefits
Enhanced Performance: Elevates gas turbine performance through advanced NOx detection and emergency overspeed protection.
Improved Efficiency: Monitors and controls critical parameters to minimize system losses and optimize overall turbine performance.
Enhanced Reliability: Advanced firmware and hardware processing capabilities ensure reliable operation and reduce the risk of downtime.
Streamlined Maintenance: Real-time monitoring and diagnostic capabilities enable early issue detection and resolution, enhancing overall system maintenance.
How it Improves Performance of GE Mark Systems
The DS200SDCCG5A is not just a component, but a key player in enhancing the performance of GE Mark systems, providing advanced control and monitoring capabilities.Â
By meticulously monitoring and controlling critical parameters, this card minimizes system losses, optimizes turbine performance, and ensures reliable operation, reducing downtime and enhancing overall system efficiency.
Applications
The DS200SDCCG5A finds its niche in a diverse array of applications, including:
Power Generation: Widely utilized in power generation facilities such as power plants and cogeneration facilities.
Oil and Gas: Integral to turbine-driven compressors and pumps within the oil and gas industry to ensure reliable and efficient operation.
Marine: Essential in marine applications for ship propulsion systems and auxiliary power generation.
Maintenance Best Practices
Regular Software Updates: Consistent software updates are essential to maintain compatibility with the latest turbine control systems.
Routine Hardware Maintenance: Regular hardware maintenance ensures the card remains in optimal working condition.
Monitoring and Diagnostic Capabilities: Leverage real-time monitoring and diagnostic features for early issue detection and resolution.
Effective Troubleshooting: Utilize jumpers, connectors, and standoffs for troubleshooting and system expansion, ensuring seamless operation and maintenance of the DS200SDCCG5A.
By diligently adhering to these meticulous maintenance practices, you can ensure the DS200SDCCG5A remains a reliable and efficient component, contributing to the seamless operation and longevity of gas turbines within the GE Mark system.
Frequently Asked Questions about DS200SDCCG5A
What is the primary function of the DS200SDCCG5A?
The DS200SDCCG5A is an input/output (I/O) card located in the C core of the GE Speedtronic MKV panel. It is primarily responsible for NOx detection and emergency overspeed protection.
What is the role of the DS200SDCCG5A in the Mark V system?
The DS200SDCCG5A serves as the primary controller for the drive system, regulating and controlling the drive’s operation.
How many microprocessors does the DS200SDCCG5A have?
The DS200SDCCG5A is populated with three microprocessors.
What is the purpose of the EPROM connectors on the DS200SDCCG5A?
The five EPROM connectors on the DS200SDCCG5A are used for storing configuration software, with four modules storing factory-assigned parameters and one module for user or servicer-assigned configurations.
What is the significance of the jumpers on the DS200SDCCG5A?
The jumpers on the DS200SDCCG5A are used to configure the board and aid in troubleshooting.
What are the connectors on the DS200SDCCG5A used for?
The connectors on the DS200SDCCG5A are used to attach auxiliary cards, which can enhance signal processing capabilities or enable local area network connectivity.
What is the purpose of the standoffs on the DS200SDCCG5A?
The standoffs on the DS200SDCCG5A are used to secure auxiliary cards in place.
How does the DS200SDCCG5A improve turbine performance?
The DS200SDCCG5A enhances turbine performance by providing advanced NOx detection and emergency overspeed protection, ensuring reliable and efficient operation.
What is the role of the DS200SDCCG5A in the CSP?
The DS200SDCCG5A is part of the CSP (Control and Protection System) in the GE Speedtronic MKV panel, which controls and protects the turbine.
What is the significance of the RAM on the DS200SDCCG5A?
The RAM on the DS200SDCCG5A allows multiple microprocessors to access and process control signals simultaneously.
How does the DS200SDCCG5A manage configuration parameters?
The DS200SDCCG5A manages configuration parameters through five EPROM connectors, with four modules storing factory-assigned parameters and one module for user or servicer-assigned configurations.
What is the purpose of the firmware on the DS200SDCCG5A?
The firmware on the DS200SDCCG5A is used to perform specific tasks involved in drive control processing.