DS200TCCAG1A Common Analog I/O Board
IN STOCK
REMAN
REPAIR
NEW
Part Number: DS200TCCAG1A
Manufacturer: General Electric
Series: MKV
Request a Quote
DS200TCCAG1A Common Analog I/O Board
The DS200TCCAG1A is a Common Analog I/O Board designed to monitor various analog signals, such as thermocouples, RTDs, and milliamp inputs, which are crucial for monitoring the performance and health of gas turbines. It includes cold junction filtering to improve the accuracy of temperature measurements from thermocouples. It is also used to monitor shaft voltage and current, which are essential parameters for monitoring the operation of gas turbines.
The board provides high-speed networked I/O for simplex, dual, and triple-redundant systems, making it suitable for various industrial automation applications. It is a flexible platform that can be used for multiple applications, including gas turbine control systems.
Manufacturer: General Electric (GE)
Series: Mark V
Part Number: DS200TCCAG1A
Product Type: Terminal Board
Country/Region of Manufacture: United States
Manual: GEH-6153
Functional Description: Analog I/O Module
Features
Monitoring Thermocouples, RTDs, and Milliamp Inputs: The DS200TCCAG1A is designed to monitor various analog signals such as thermocouples, RTDs, and milliamp inputs, which are crucial for monitoring the performance and health of gas turbines.
Cold Junction Filtering: The board includes cold junction filtering, which improves the accuracy of temperature measurements from thermocouples.
Shaft Voltage and Current Monitoring: The DS200TCCAG1A is also used to monitor shaft voltage and current, which are essential parameters for monitoring the operation of gas turbines.
High-Speed Networked I/O: The board provides high-speed networked I/O for simplex, dual, and triple-redundant systems, making it suitable for various industrial automation applications.
Flexible Platform for Multiple Applications: The Mark V series, which includes the DS200TCCAG1A, is a flexible platform that can be used for multiple applications, including gas turbine control systems.
Static-Sensitive Design: The DS200TCCAG1A is a static-sensitive board requiring minimal handling to prevent damage.
Backed by Warranties: The board is supported by a three-year warranty from AX Control and a two-year warranty from Radwell.
Compatibility
The DS200TCCAG1A is designed to be compatible with the GE Mark V Series of gas turbine control systems. It is a critical component in these systems, providing essential monitoring and control functions.
Thanks to its high-speed networked I/O capabilities, the board is also compatible with various industrial automation applications. It can be used in simplex, dual, and triple-redundant systems, ensuring reliable operation in mission-critical applications.
Additionally, the DS200TCCAG1A is compatible with the I/O Configuration Editor software, which configures thermocouples, RTDs, milliamp inputs and outputs, and shaft voltage and current settings.
Benefits
Improved Monitoring and Control: The DS200TCCAG1A provides enhanced monitoring and control capabilities for gas turbine systems, ensuring reliable operation and optimizing performance.
Increased Accuracy: The board’s cold junction filtering feature improves the accuracy of temperature measurements from thermocouples, leading to more precise monitoring of gas turbine performance.
Flexibility: The DS200TCCAG1A’s compatibility with various industrial automation applications and its ability to be used in simplex, dual, and triple-redundant systems make it a versatile solution for multiple applications.
Ease of Configuration: The I/O Configuration Editor software makes configuring the board’s settings easy, reducing setup time and complexity.
Reliability: The DS200TCCAG1A is backed by warranties from AX Control and Radwell, ensuring reliable performance and peace of mind for users.
Applications
The DS200TCCAG1A is primarily used in GE Mark V gas turbine control systems, where it plays a critical role in monitoring and controlling the operation of gas turbines. However, its versatility and compatibility with various industrial automation applications make it suitable for use in a wide range of industries and applications, including:
Power Generation: The DS200TCCAG1A is essential for monitoring and controlling gas turbines in power generation facilities.
Oil and Gas: The board can be used in gas turbine-driven compressors and pumps in the oil and gas industry.
Manufacturing: The DS200TCCAG1A can be used in industrial automation applications, such as monitoring and controlling processes in manufacturing facilities.
Aerospace: The board may be used in gas turbine-powered aircraft and ground support equipment.
Maintenance Best Practices
To ensure optimal performance and longevity of the DS200TCCAG1A board, it is essential to follow proper maintenance best practices:
Handle with Care: The DS200TCCAG1A is a static-sensitive board, so handling it with care and minimizing exposure to static electricity to prevent damage is crucial.
Follow Installation Guidelines: Ensure the board is installed according to the manufacturer’s instructions and that all connections are secure and properly grounded.
Perform Regular Inspections: Regularly inspect the board for signs of wear, damage, or loose connections and address any issues promptly.
Keep Software Up to Date: Ensure that the I/O Configuration Editor software used to configure the board is up-to-date and that any necessary updates are applied.
Maintain Environmental Conditions: To prevent premature failure, ensure that the board is operated within the specified environmental conditions, such as temperature and humidity ranges.
By following these maintenance best practices, users can ensure the reliable and long-lasting performance of the DS200TCCAG1A board in their GE Mark V gas turbine control systems and other industrial automation applications.
Frequently Asked Questions about DS200TCCAG1A
What is the DS200TCCAG1A?
The DS200TCCAG1A is a Common Analog I/O Board manufactured by General Electric as part of the Mark V Series, which is used in gas turbine control systems.
What is the primary function of the DS200TCCAG1A?
The primary function of the DS200TCCAG1A is to monitor various analog signals, such as thermocouples, RTDs, and milliamp inputs, which are crucial for monitoring the performance and health of gas turbines.
What are the key features of the DS200TCCAG1A?
Key features include monitoring thermocouples, RTDs, and milliamp inputs, cold junction filtering, shaft voltage and current monitoring, and high-speed networked I/O for simplex, dual, and triple-redundant systems.
Is the DS200TCCAG1A a static-sensitive board?
The DS200TCCAG1A is a static-sensitive board requiring minimal handling to prevent damage.
What is the recommended storage condition for the DS200TCCAG1A?
The recommended storage condition is in a static-sensitive storage box in recommended conditions.
Can the DS200TCCAG1A be refurbished?
Yes, the DS200TCCAG1A can be refurbished, which involves replacing aging and commonly failing components, applying TIL modification if necessary, reflowing solder to eliminate dry solder, thoroughly industrial-standard cleaning of the card, and applying a protective coating.
How is the DS200TCCAG1A tested?
The DS200TCCAG1A is tested in an actual OEM system setup to ensure 100% reliability. All inputs and outputs are individually verified for their functionality.
How should the DS200TCCAG1A be handled?
The DS200TCCAG1A should be handled with proper ESD safety precautions, minimizing hands-on contact with the PCB, especially in the conducting area, and wearing antistatic gloves.
What are the different buying options for the DS200TCCAG1A?
The DS200TCCAG1A is available in new, certified, refurbished, and used conditions.
Can the DS200TCCAG1A be repaired?
The DS200TCCAG1A can be repaired using proper tools and experts in a controlled environment. All parts needed for fixing the board are in stock, and the replacement components are industrial grade and meet or exceed OEM standards.
How long does it take to repair the DS200TCCAG1A?
The repair time for the DS200TCCAG1A is expedited, and same-day turnaround repair service is available upon request.
What is the functional verification test for the DS200TCCAG1A?
The functional verification test for the DS200TCCAG1A involves testing all inputs and outputs individually for their functionality in an actual OEM system setup to ensure 100% reliability.