DS200TCQAG1BFD RST Analog I/O Board

The DS200TCQAG1BFD is designed to handle various analog signals, including LVDT inputs, servo valve outputs, thermocouple inputs and outputs, 420 mA inputs and outputs, vibration inputs, relay driver outputs, pulse inputs, voltage inputs, generator and line signals. The board contains circuitry for pulse rate inputs, 420 and 01 mA input signals, and driving 420 mA outputs. Additionally, it provides a thermocouple cold junction reference and calculates the actual temperature measured by thermocouples.

Looking for a Different Part?

Frequently Asked Questions about DS200TCQAG1BFD:

What is the DS200TCQAG1BFD?

The DS200TCQAG1BFD is a drive control board designed for use with GE Speedtronic Mark V series systems.

What are the primary applications of the DS200TCQAG1BFD?

The DS200TCQAG1BFD is used in gas turbine control, power generation, and industrial automation systems.

What type of signals does the DS200TCQAG1BFD handle?

The DS200TCQAG1BFD can handle various analog signals, including LVDT inputs, servo valve outputs, thermocouple inputs and outputs, 420 mA inputs and outputs, vibration inputs, relay driver outputs, pulse inputs, voltage inputs, generator, and line signals.

What are the connectors on the DS200TCQAG1BFD?

The DS200TCQAG1BFD has four 34-pin connectors, two 40-pin connectors, and six jumpers.

What are the LEDs on the DS200TCQAG1BFD used for?

The six LEDs on the DS200TCQAG1BFD provide status information about the board’s health and processing activities.

How is the DS200TCQAG1BFD installed?

The DS200TCQAG1BFD is installed in the board cabinet in the drive, where it is secured using screws.

How should jumpers be set on the DS200TCQAG1BFD?

Jumpers on the DS200TCQAG1BFD should be set to match the settings on the original

board to ensure proper functionality.

What is the purpose of the thermocouple circuit on the DS200TCQAG1BFD?

The thermocouple circuit on the DS200TCQAG1BFD provides a cold junction reference and calculates the actual temperature measured by thermocouples.

How does the DS200TCQAG1BFD handle pulse rate inputs?

The DS200TCQAG1BFD adjusts and conditions pulse rate inputs to read from the TCQC board through the JE connector.

What are the 420 mA input circuits used for?

The 420 mA input circuits on the DS200TCQAG1BFD are used to read signals from the TBQC terminal board.

What are the 420 mA output circuits used for?

The 420 mA output circuits on the DS200TCQAG1BFD drive outputs to the TBQC terminal board.

How should the DS200TCQAG1BFD be handled during maintenance?

The DS200TCQAG1BFD is a static-sensitive board and should be handled with antistatic gloves and precautions to prevent damage.

What kind of support is available for the DS200TCQAG1BFD?

The manufacturer supports the DS200TCQAG1BFD, which can be repaired and refurbished by authorized service centers.