Feature | Description |
Manufacturer | General Electric (GE) |
Model Number | IS200TBCH1B |
Dimensions | 7.0 inches x 13.0 inches |
Description | Terminal Board |
Processor | 1 GHz or faster (2 GHz recommended) |
Compatibility | VTUR board in Mark VI system |
Display Resolution | Minimum 1280×1024 |
Internet Connection | Required for BenchVue application and updates |
The IS200TBCH1B Terminal Board is vital to facilitate communication and connection between various elements within the GE Mark VI control system.
It serves as a bridge, ensuring seamless interaction and coordination among system components, contributing to overall efficiency and performance.
The IS200TBCH1B Terminal Board operates by establishing connections and enabling communication pathways between different components within the GE Mark VI control system.
It ensures that data and signals flow seamlessly, allowing for coordinated system operation and optimal performance.
The IS200TBCH1B Terminal Board is specifically designed for compatibility with the GE Mark VI control system environment.
It seamlessly integrates with other components and software applications, ensuring smooth operation and optimal performance.
Before beginning the installation process, ensure all necessary components and tools are readily available. This includes the IS200TBCH1B Terminal Board, cables with molded plugs, power plugs, and any other accessories required for installation.
Identify the VME Rack where the VTUR board is housed. This is where the TBCH terminal board will be connected.
Connect the TBCH terminal board to the designated slots in the VME Rack using the provided cables with molded plugs. Ensure that the connections are secure and properly seated to avoid potential issues during operation.
Connect the trip solenoids’ wires to the first I/O terminal block on the TBCH terminal board. If additional components are to be connected, use the second terminal block accordingly.
Connect and power specific plugs (J3, J4, J5) for power distribution. To prevent electrical issues, ensure that the power supply meets the manufacturer’s specifications.
Utilize the J1 plug to connect the 125 V DC power supply specifically for the trip solenoids. This ensures proper power distribution and functionality of the terminal board.
Use the J2 socket to send power to the TREG board, ensuring that all components receive the necessary power supply for operation.
Once all connections have been made, double-check to ensure all cables are securely connected and properly seated. Loose connections can lead to intermittent faults or errors during operation.
Perform diagnostic checks to ensure the TBCH terminal board’s proper functioning. This involves verifying signal pathways, power distribution, and other relevant parameters to ensure optimal performance.
If experiencing issues during operation, the first step is to check all connections to the TBCH terminal board. Ensure cables are securely connected and properly seated to prevent intermittent faults or errors.
Confirm that the TBCH terminal board receives the correct power supply according to the manufacturer’s specifications. An inadequate power supply can lead to operational issues and malfunctions.
Check the backplane jumper configuration to ensure it is correctly set up. Misconfigured jumpers can result in bus timeout errors or device not-found issues during installation or operation.
Resolve any conflicts with interrupt vectors, which can lead to spurious interrupts or system panics. Adjusting interrupt settings can help alleviate these issues.
Ensure proper Ethernet cable connection without any obstructions. Issues with Ethernet connectivity can lead to network-related errors and communication issues within the system.
Update CPU Board Revision: If encountering errors such as “Bad Trap” or “Bus Error,” ensure the CPU board is updated with the latest revision. Outdated CPU board revisions can lead to compatibility issues and operational errors.
Investigate and address errors indicating “No such device” to ensure proper invocation and system functionality.
If experiencing slow NFS traffic or “NFS Server Not Responding” messages, check NFS parameters and configurations to optimize network file system performance.
Ensure the correct location and linking of the kernel to prevent boot process failures. Errors related to kernel location can hinder the startup process and overall system operation.
Verify the native Ethernet interface is correctly configured and connected to Ethernet to prevent system hang-ups and communication issues during reboots.
What are the system requirements for installing IS200TBCH1B?
System requirements include Windows 10 (32-bit and 64-bit), 1 GHz processor, 1 GB RAM for 32-bit or 2 GB for 64-bit, and minimum 1280×1024 display resolution.
What are the common issues faced while installing IS200TBCH1B?
Common issues include backplane jumper configuration errors, improper seating of boards and cables, Ethernet cable interference, interrupt vector conflicts, and device not found errors.
What is the troubleshooting process for IS200TBCH1B?
Troubleshooting involves checking connections, verifying power supply, inspecting backplane jumpers, addressing interrupt vector conflicts, reviewing Ethernet connectivity, updating CPU board revision, and resolving device not found errors.
What are the applications of IS200TBCH1B?
IS200TBCH1B is used in the GE Mark VI control system to facilitate connections and communication between various components, ensuring smooth operation in industrial processes.
What is the function of IS200TBCH1B?
IS200TBCH1B serves as a terminal board within the GE Mark VI control system. It facilitates connections and communication between components for smooth operation.
What is the compatibility of IS200TBCH1B with other software or hardware?
IS200TBCH1B is compatible with components and software applications specific to the GE Mark VI control system, ensuring seamless integration and operation within the system architecture.