IS200TRPGH1A Primary Trip Termination Board
IN STOCK
REMAN
REPAIR
NEW
Part Number: IS200TRPGH1A
Manufacturer: General Electric
Series: MKVI
Request a Quote
IS200TRPGH1A Primary Trip Termination Board
The IS200TRPGH1A module functions as a primary trip termination board within the gas turbine control system.Â
It interfaces with the primary turbine protection controller (VTUR or PTUR) and plays a pivotal role in managing emergency trip scenarios.Â
The module features 12 relays arranged in two rows of six, which facilitate the interface with the primary protection system and accommodate inputs from flame detectors.Â
In Triple Modular Redundant (TMR) applications, the module employs relay ladder logic in two out of three voting circuits to enhance redundancy and reliability.
Part Number: IS200TRPGH1A
Manufacturer: General Electric
Series: Mark VI
Relay Configuration: 12 relays arranged in two rows of six
Terminal Blocks: Two terminal blocks with 24 metal terminals each
Power Supply: 125 V dc
Features:
~12 relays aligned in two rows of six
~Terminal blocks with 24 metal terminals each
~Metal oxide varistors for protection
~Three white jumper ports for configuration
~Various connectors for integration
~Rectangular card design for easy installation
~Typically comes with a 3-year warranty
Compatibility:
The IS200TRPGH1A module is compatible with the VTUR board in the GE Mark VI system.Â
It supports both simplex and TMR applications, providing flexibility in system configurations.Â
The module seamlessly integrates into the system using cables with molded plugs, ensuring smooth operation within the gas turbine control environment.
Applications:
The IS200TRPGH1A module finds extensive applications within gas turbine control systems, including:
Primary Trip Termination: Serving as a Gas Turbine Primary Trip Termination Board, the module interfaces with the primary turbine protection controller to manage emergency trip scenarios effectively.
Simplex and TMR Applications: Supporting both simplex and Triple Modular Redundant (TMR) applications, the module offers versatility in system configurations, ensuring reliable operation in various environments.
Emergency Trip Devices (ETDs): Working in conjunction with other modules, such as the TREG board, the IS200TRPGH1A ensures the proper functioning of emergency trip devices, safeguarding the turbine system against critical failures.
Flame Detector Inputs: The module accommodates inputs from flame detectors, monitoring signals and providing voltage pulses to the primary protection system, enhancing the safety and reliability of the control system.
Relay Control: Utilizing the TRPG relays, the module plays a crucial role in tripping main protection solenoids, ensuring prompt response and protection against potential hazards.
Voting Circuits: In TMR applications, the module utilizes relay ladder logic voting circuits to enhance redundancy and reliability, minimizing the risk of system failures during critical operations.
Maintenance:
Maintenance of the IS200TRPGH1A module is essential to ensure optimal performance and reliability within the gas turbine control system.Â
Key maintenance tasks include:
~Regular inspection for signs of wear, damage, or corrosion
~Cleaning of the module and its components to prevent dust buildup
~Maintenance of relays, capacitors, resistors, and terminal blocks
~Ensuring proper power supply and software updates
~Keeping detailed records of maintenance activities for regulatory compliance and historical tracking
By adhering to these maintenance guidelines, operators can ensure the IS200TRPGH1A module operates reliably and efficiently, contributing to the overall performance and safety of the gas turbine control system.
Frequently Asked Questions
What is the part number of the IS200TRPGH1A module?
The part number of the IS200TRPGH1A module is IS200TRPGH1A.
Who is the manufacturer of the IS200TRPGH1A module?
The IS200TRPGH1A module is manufactured by General Electric.
What series does the IS200TRPGH1A module belong to?
The IS200TRPGH1A module is part of the GE Speedtronic Mark VI series.
What is the function of the IS200TRPGH1A module?
The IS200TRPGH1A module functions as a Primary Trip Termination Board in the GE Mark VI gas turbine control system.
How many relays are on the IS200TRPGH1A module?
The IS200TRPGH1A module features twelve relays (also called contactors) arranged in two rows of six.
What type of relays are used on the IS200TRPGH1A module?
The relays on the IS200TRPGH1A module are white and black, with a silver metal wire on top of each relay.
What other components are on the IS200TRPGH1A module?
The IS200TRPGH1A module is populated with metal oxide varistors, three white jumper ports, small integrated circuits, and small resistors.
How many terminal blocks are on the IS200TRPGH1A module?
The IS200TRPGH1A module has two terminal blocks, each with 24 numbered metal terminals (48 total).
What is the purpose of the IS200TRPGH1A module within the GE Mark VI system?
The IS200TRPGH1A module serves as the interface between the primary turbine protection controller (VTUR or PTUR) and the Emergency Trip Devices (ETDs).
Does the IS200TRPGH1A module support both Simplex and Triple Modular Redundant (TMR) applications?
Yes, the IS200TRPGH1A module supports both Simplex and TMR applications within the GE Mark VI system.
What type of warranty is typically offered for the IS200TRPGH1A module?
The IS200TRPGH1A module typically comes with a 3-year warranty for reliability and assurance.
How can the IS200TRPGH1A module be obtained?
The IS200TRPGH1A module can be purchased as a new surplus or reconditioned replacements from authorized suppliers.
Does the supplier offer repair services for the IS200TRPGH1A module?
Yes, the supplier often offers repair services for defective IS200TRPGH1A modules as a cost-effective alternative to replacement.