IC Spares VFD rental program allows users to rent 6000HP VFD while their VFD is being repaired or a new VFD is being delivered. We rent Siemens Perfect Harmony GH180 VFDs (Variable Frequency Drives) that can operate from 2000HP to 9000HP at 4160 or 6900 volts. The mobile VFD can be deployed with 24-hours notice. Contact IC Spares to speak with one of our technicians about renting a VFD 6000HP rental for your application.
Mobile VFDs deliver superior versatility, efficiency, and process availability for the most demanding applications. The Siemens Perfect Harmony GH180 VFD rental with 6000HP sets the standard for reliability. It draws on decades of Siemens/Innomotics experience with a wide range of 6000 HP VFD rental applications from electric motors at a gas compressor station to induced draft fans in a mill.
Frequency converters or also named variable frequency drives are electronic devices that convert a (more or less) fixed frequency and voltage into a variable frequency and voltage. This devices allow electric motors to be operated with a variable speed.
Today, frequency converters are used practically everywhere to operate single-phase and three-phase electric motors with a variable speed. And not just in industrial environments, but in everyday life. Starting from very low power ratings to control washing machine drums up to medium power ratings for pumps used in municipal water supplies.
Variable frequency drives are used in the industrial landscape for the following applications, for example:
These functions are used in many industry sectors:
Motor starters – also called soft starters or soft starting devices – are not frequency converters, but devices that simply reduce the voltage. You use them if your motors are connected to line supplies that are either very weak, or to which other loads are connected that are very sensitive to voltage fluctuations. On the other hand, you must use a frequency converter if you wish to continuously control the speed of an electric motor. This offers some significant advantages: Flexibility, process optimization and energy saving.
You can often see terms such as frequency converter, converter, rectifier, inverter, drive converter etc. in literature:
Here is a brief explanation of some of the commonly used terms used in conjunction with frequency converters:
Frequency converters to convert the frequency of an alternating voltage or three-phase voltage (single-phase or three-phase) into an AC voltage or three-phase voltage with a different or varying frequency.
A rotating frequency converter is an electromechanical arrangement comprising a motor and a generator, also called motor-generator set.
A converter/frequency converter is an electric circuit with which one or several electrical variables can be changed, for example voltage, current and frequency.
A rectifier is a circuit made up of components to convert AC current or three-phase current into DC current. Converter arrangements, which are used for energy recovery or for braking, must have an active converter at the input that is equipped with controllable power semiconductors.
Inverters are used to convert DC current into AC current or three-phase current.
Pulsed converters or PWM converters/inverters (PWM: pulse-width modulation): Using this technique, by suitably selecting the pulse and pause duration (duty cycle or also called mark-space ratio), an output voltage can be obtained. Depending on the pulse frequency, the mean value of this voltage has an almost perfect sinusoidal waveform.
Voltage-source DC link converters comprise an uncontrolled or controlled rectifier, a DC link with capacitors and an inverter (motor-side inverter). The motor-side inverter (or also just called inverter) generates a three-phase system with adjustable frequency and voltage that impresses a current, which in turn develops the specified motor torque.
The two main components – line-side converter and motor-side inverter – are connected in the DC link. For current-source DC link converters, this comprises a reactor to smooth the current, and for voltage-source DC link converters, a capacitor to smooth the voltage.
The speed of an electric motor depends on the frequency of the supply voltage and the number of poles that the rotor has. These attributes are fixed (with the exception of pole-changing motors – sometimes called multi-speed motors) and cannot be changed.
Using a frequency converter, the motor voltage and its frequency can be controlled over a wide range, and in turn, its speed.
Operated with a converter, the motor speed can be controlled, the motor can be braked and energy can be recovered (regenerative feedback into the line supply).
In addition to a frequency converter and motor, several other components are required to engineer a variable-speed drive system:
The following components are possibly required to engineer a variable-speed drive system:
As a result of the closed-loop control, the motor precisely provides the power that the process requires – and no more. For applications where braking is required, you must select a converter that can feed back the electrical energy – that is generated when braking – into the line supply.
Examples:
You use a braking resistor if your drive system must be braked or brought to a standstill – especially when a fault situation is involved. Resistors located in the DC link absorb the drive train kinetic energy and convert this into heat (thermal energy).You should not confuse a braking resistor with a holding brake. A holding brake only ensures that the driven machine that you are controlling does not cause the drive train to move (for example, important for cranes and inclined conveyor sections).
Two filter types come into consideration when using a frequency converter:
Line filters prevent harmonics, generated by a frequency converter, from being injected back into the line supply and disturbing other loads connected to the same line supply. Depending on the requirements of your system or your power utility company, line filters can either be LC filters (sine-wave filters) or line reactors. The latter are sometimes called commutating reactors.
Output filters protect your motors against the steep voltage edges inherently generated by an inverter. These filters are required if the cable between the inverter and the motor is very long. In cases such as these, reflections and voltage transients can occur on cables, which can destroy the insulation of your motor. You can use either sine-wave filters or dv/dt limiting reactors.
In addition to product standard IEC 61800-5-1, which applies to adjustable speed power drive systems (variable-speed drive systems), standards, regulations as well as country-specific specifications, which are specified by users, plant and system operators and power utility companies, must be increasingly taken into account. These include requirements relating to the line quality for example. The predominant reason for this is that increasingly active converters (with controllable power semiconductors) are being connected to grids, for example, for photovoltaic and wind turbine systems. Other examples include Namur connections, to address connection requirements relating to areas of the chemical industry, as well as requirements relating to ruggedness as are demanded for maritime applications, and which are verified in the form of marine certifications.
PHONE: 1 (310) 985-7340
EMAIL: SALES@IC-SPARES.COM