SIEMENS 8000 HP 6900 V

Variable Frequency Drive

  • 8000 HP Variable Frequency Drive
  • Perfect Harmony GH180
  • Input: 6900 Volt, 60Hz, 3PH, 595A
  • Output: 0-6900 Volt, 0-66Hz, 3PH, 660A
  • Dimensions: 308″ W x 54″ D x 129″
  • Condition: New
  • Upgraded with the NXGPro controls
  • 18 Power Cells

Looking for a Different Part?

Frequently Asked QUestions

In what ways can a Siemens Perfect Harmony GH180 8000 Horsepower 6900V Variable Frequency Drive improve production?

  • Precise Speed Control: Siemens Perfect Harmony GH180 8000 HP 6900V VFDs can adjust motor speed precisely based on real-time process needs, enabling fine-tuning of production rates and optimizing operations across different stages.
  • Energy Efficiency: By only using the required power to achieve the desired speed, Siemens Perfect Harmony GH180 VFDs with NXGpro controls can significantly reduce energy consumption, especially in applications like pumps and fans where variable loads are common.
  • Soft Starts and Stops: Siemens 6900 Volt 8000 Horsepower VFDs provide smooth acceleration and deceleration, reducing stress on equipment and extending its lifespan while minimizing mechanical shock.
  • Improved Process Accuracy: By maintaining consistent speeds throughout a production process, Siemens Perfect Harmony VFDs with NXGpro controls contribute to better product quality and reduced waste.
  • Flexibility in Production Rates: Manufacturers can quickly adjust production speeds based on demand fluctuations without needing major equipment modifications, thanks to Siemens Perfect Harmony GH180 Variable Frequency Drives.
  • Reduced Downtime: Siemens Perfect Harmony 8000 HP 6900V VFDs often include motor protection features that can help prevent equipment failures and minimize production interruptions.

What are the input and output of the Siemens Perfect Harmony GH180 6900V 8000 HP Variable Frequency Drive?

  • Input: 6900 Volt, 60Hz, 3PH, 595A
  • Output: 0-6900 Volt, 0-66Hz, 3PH, 660A

Can the Siemens 6900V 8000 HP Variable Frequency Drive be used instead of a soft starter?

If your application requires variable speed control, a Siemens Perfect Harmony GH180 VFD is the better option.

What makes Siemens Perfect Harmony 6900 Volt 8000 Horsepower VFDs energy efficient?

By adjusting motor speed to match application requirements, Siemens 6900V 8000 HP Perfect Harmony GH180 Variable Frequency Drives minimize energy consumption and reduce operational costs.

Can Siemens Perfect Harmony GH180 8000 Horsepower 6900V Variable Frequency Drives handle multi-drive systems?

Yes, Siemens 6900V 8000 HP VFDs are capable of controlling complex multi-drive systems efficiently.

What is Safe Torque Off (STO) in Siemens Perfect Harmony GH180 6900V 8000 HP VFDs?

STO is a safety feature that stops the motor torque without disconnecting the power, ensuring safe operation.