SIEMENS GEN4E 3000 HP 12470 V

Variable Frequency Drive

  • 3000 HP Variable Frequency Drive
  • GEN4E
  • Input: 12470 Volts
  • Output: 0-6600 Volts
  • Amps: 750 amps
  • Dimensions: 308″ W x 54″ D x 129″
  • Condition: New
  • System/PN: ASE48367976

Looking for a Different Part?

Frequently Asked QUestions

How does a Siemens GEN4E 3000 HP 12470V Variable Frequency Drive enhance production?

  • Precision Speed Control: Siemens GEN4E 3000 HP 12470V VFDs provide accurate motor speed regulation based on real-time operational requirements, helping you optimize production rates and overall efficiency.
  • Energy Conservation: By supplying only the power needed to reach the desired speed, the NXGpro-equipped Siemens GEN4E 3000 HP VFD can considerably reduce energy consumption, especially in fan or pump applications where load demands vary.
  • Gentle Starts and Stops: Siemens 12470 Volt 3000 Horsepower VFDs ensure smooth motor acceleration and deceleration, decreasing mechanical stress and wear on equipment, thus extending its operational life.
  • Consistent Process Quality: Keeping speeds stable throughout the production process fosters consistent product quality and minimizes waste, thanks to the reliable NXGpro controls built into Siemens GEN4E VFDs.
  • Flexible Production Rates: The scalable design of GEN4E VFDs allows for quick adaptation of production speeds to meet market or operational changes, without major modifications to existing equipment.
  • Reduced Downtime: Siemens GEN4E 3000 HP 12470V VFDs often include comprehensive motor protection features that help prevent equipment failures and reduce production interruptions.

What are the input and output specifications for the Siemens GEN4E 12470V 3000 HP Variable Frequency Drive?

Input: 12470 Volt, 60Hz, 3PH, 595A
Output: 0–12470 Volt, 0–66Hz, 3PH, 660A

Can the Siemens 12470V 3000 HP Variable Frequency Drive replace a soft starter?

If your application demands variable speed control, a Siemens GEN4E 3000 HP VFD is the superior choice. It not only delivers the advantages of soft starting but also provides the added benefit of speed adjustment.

Why are Siemens 12470 Volt 3000 HP VFDs energy efficient?

By aligning motor speeds with the exact process requirements, Siemens 12470V 3000 HP GEN4E Variable Frequency Drives help lower energy usage and cut overall operational costs.

Are Siemens GEN4E 3000 HP 12470V Variable Frequency Drives suitable for multi-drive environments?

Yes. The Siemens 12470V 3000 HP GEN4E VFD is fully capable of managing complex multi-drive setups, offering high reliability and efficient control.

How does Safe Torque Off (STO) work in Siemens GEN4E 12470V 3000 HP VFDs?

STO is a built-in safety function that halts motor torque production without fully disconnecting power, ensuring a safe and controlled operating environment.