VFD Rental: 1500HP Mobile VFD Available
Yaskawa MV1000 NEMA 3R Outdoor Medium Voltage VFD
IC Spares VFD rental program allows users to rent a VDF while their VFD is being repaired or a new VFD is being delivered. We rent Yaskawa MV1000 NEMA 3R Outdoor Medium Voltage VFD (Variable Frequency Drive) that can operate from 250HP to 1500HP at 4160 volts. The mobile VFD can be deployed in 24-hours notice. Contact IC Spares to speak with one of our technicians about a mobile VFD rental for your application.
Mobile VFDs deliver superior versatility, efficiency, and process availability for the most demanding applications. The Yasawa MV1000 drive sets the standard for reliability. It draws on decades of experience with a wide range of industry applications, from electric motors at a gas compressor station to induced draft fans in a mill.
Yaskawa MV1000 NEMA 3R Outdoor Medium Voltage VFD for Rent
The Yaskawa MV1000 NEMA 3R variable frequency drive (VFD) offers high performance and proven Yaskawa reliability. The medium voltage drive is based on the user-friendly A1000 control platform with enhanced performance and features. Below is a detailed specifications on the mobile VFD: input switchgear, heat exchanger, transformer, control, transformer, and power cell.
Yaskawa’s Smart Harmonics™ Technology input isolation transformer and 9 level output for 4kV drives (17 level line-to-line), the biggest traditional issues with the application of medium voltage VFD all but disappear. The MV1000 mobile variable frequency drive is a compact, all-in-one package including (optional) input switchgear, ideal for new, retrofit or rental installations.
- Non-load break switch
- E-Rated current limiting fuses
- Vacuum contactor for load interruption
- All UL / CSA rated components
- Viewing window
- Fully sealed
- Air to air heat transfer
- High efficiency
- Easy to maintain
- 36-pulse patented design
- Galvanic isolation
- Double insulated windings
- Winding temperature monitoring and protection
- Surge protected primary
- Easy access to most control devices
- Control wiring interface
- Main processor
- Digital input/outputs
- Isolated analog inputs/outputs
- Fan control/monitoring boards
- Contacts and circuit boards for fans
- Control voltage power supplies
- Two cell per phase
- Fuse protection on each cell
- Control and monitoring via single fiber optic cable per cell
- IGBT temperature monitors
- Easy cell replacement in 15 minutes
1500HP mobile VDF for rent for the following industries:
- Midstream Compressors & Pumps Medium Voltage VFD
- Oil Field Water Injection Pumps Medium Voltage VFD
- High Efficiency Fracking Pumps Medium Voltage VFD
- Electrical Submersible Pumps Medium Voltage VFD
- Gas Injection Medium Voltage VFD
- Slurry Pumps Medium Voltage VFD
- Ventilation Fans Medium Voltage VFD
- Conveyors Medium Voltage VFD
- Crushers Medium Voltage VFD
- Dryer Fans Medium Voltage VFD
- Conveyors Medium Voltage VFD
- Fans Medium Voltagee VFD
- Rotary Kilns Medium Voltage VFD
- Pumps Medium Voltage VFD
- Crushers Medium Voltage VFD
- Pumps VFD
- Compressors VFD
- Extruders VFD
- Fans VFD
- Induced Draught (ID) Fan VFD
- Foroced Draught (FD) Fan VFD
- Electric Motor VFD
- Electric Motor Medium Voltagee VFD
- Pumps Medium Voltage VFD
- Electric Motor VFD
- Induced Draught (ID) Fan VFD
- Foroced Draught (FD) Fan VFD
- Compressors Medium VoltageVFD
- Electric Motor VFD
- Winders FVD
- Realers VFD
- Coilers VFD
Mobile Yaskawa Medium Voltage VFD Specifications for Rent:
Control Methods: | V/f Control (V/f), Open Loop Vector Control (OLV), Closed Loop Vector Control (CLV) |
Frequency Control: | Range 0.01 to 120 Hz |
Frequency Accuracy (Temperature Fluctuation): | Digital input: within ±0.01% of the max output frequency (-10°C to +40°C); Analog input: within ±0.5% of the max output frequency (-10°C ± 40°C) |
Starting Torque V/f: | 130% at 3 Hz, OLV: 130% at 0.3 Hz, CLV: 130% at 0 r/min |
Speed Control Range: | V/f: 1:20, OLV: 1:100, CLV: 1:1000 |
Speed Control Accuracy: | V/f: ± 2 to 3%, OLV: ± 0.5%, (25 °C ± 10 °C), CLV: ± 0.02% (25 °C ±10 °C) |
Speed Response: | OLV: 10 Hz, CLV: 50 Hz |
Accel/Decel Time: | 0.0 to 6000.0 s (4 selectable combinations of independent acceleration and deceleration settings) |
Motor Protection: | Electronic thermal overload relay |
Momentary Overcurrent Protection: | Drive stops when output current exceeds 132% |
Overvoltage Protection: | Power Cell VPN > 1035 VDC |
Undervoltage Protection: | Power Cell VPN < 300 VDC |
Momentary Power Loss Ride-Thru: | Resumes operation if power loss is less than 2 s (standard) (UPS Required) |
Overheat Protection: | Power Cell = Thermistor, Transformer = PT100 and Thermal Switch |
Ground Fault Protection: | Electronic circuit protection |
Ambient Temperature: | -5 to +40°C (up to +50°C with output current derate) |
Humidity: | 95% RH or less (no condensation) |
Storage Temperature: | -20 to +60 ˚C (short-term temperature during transportation) |
Altitude: | Up to 2000 m without derating, up to 4000 m with output current and voltage derating |